Condition Monitoring in Thermal Power Stations

Condition Monitoring in Thermal Power Stations

Case Studies

Bari, Hemant; Thaker, Jignesh

Taylor & Francis Ltd

11/2024

292

Dura

9781032531991

Pré-lançamento - envio 15 a 20 dias após a sua edição

Descrição não disponível.
1. Introduction

2. Case Study 1: Coal Mill 2AB: Main Reducer Gearbox Bearing Deterioration - May 2020

3. Case Study 2: Booster Fan 01 (FGD): Fan Bearings Looseness - April 2020

4. Case Study 3:Coal Mill 1CD: Gearbox Intermediate Gear Damage - September 2019

5. Case Study 4:Coal Mill 1EF: Gearbox Input NDE Bearing Damage - September 2019

6. Case Study 5: Coal Mill 2CD: Output Gear Shaft Crack Detection - July 2019

7. Case Study 6: Booster Fan 01 (FGD): Fan Blade Crack Detection - May 2019

8. Case Study 7: PA Fan 2B: Fan Bearing Deterioration - April 2019

9. Case Study 8: Turbogenerator 01: In-Situ Balancing - January 2019

10. Case Study 9: SAC Compressor 2B: Motor Bearings Deterioration - July 2018

11. Case Study 10: Coal Mill 2AB: Pinion Gear Reversal - February 2018

12. Case Study 11: ID Fan 2A: Hydraulic Coupling Bearing Deterioration - October 2017

13. Case Study 12: Coal Conveyor 4A (CHP): Gearbox Input Bearing Damage - August 2017

14. Case Study 13: Coal Mill 2EF: Gearbox Foundation Deterioration - August 2017

15. Case Study 14: CW Pump 02: Motor Bearing Looseness - April 2017

16. Case Study 15: Diesel Locomotive 02: Alternator Bearings Deterioration - August 2015

17. Case Study 16: Stacker Reclaimer 01 (CHP): Motor Foundation Deterioration - June 2015

18. Case Study 17: PA Fan 2B: Motor Foundation Deterioration - November 2014

19. Case Study 18: Condensate Extraction Pump 2B: Pump Resonance - August 2014

20. Case Study 19: ID Fan Motor Trail (at Test Bench): Motor Bearing Damage - June 2014

21. Case Study 20: HP Pump C (AHP): Motor Rotor Bar Damage - June 2014

22. Case Study 21: DC Seal Oil Pump 1A: Motor Foundation Deterioration - July 2013

23. Case Study 22: Gas Turbine 01 (BSES Kerala Plant): Misalignment of Generator - October 2012

24. Case Study 23: ID Fan 1B: Motor Bearing Looseness - January 2011

25. Case Study 24: Boiler Feed Pump 1B: Misalignment of Booster Pump - January 2011

26. Case Study 25: Coal Mill 1CD: Main Motor Bearing Damage - June 2008
Este título pertence ao(s) assunto(s) indicados(s). Para ver outros títulos clique no assunto desejado.
Gearbox;Booster;Hydraulic Coupling;Fab Blade;Generator;Rotor Bar